v0.99.4
WARNING:
- The catalog format has changes. Catalog files generated with previous versions are no longer valid
BUGS:
- since HypoDD supports station ids with a maximum length of 7 chars, sometimes the realocation fails due to the station ids generated by scrtdd being too long. Now the station ids are converted before being used to create HypoDD input files
ENHANCEMENTS:
- scrtdd is not able to deal with multiple location codes for the same stations. In previous releases errors were produced when a station had more than one location codes.